56. Q. Should rapid firing be practiced?
A. No; it should not be practiced for the same reason that heavy firing is wrong. A few moments should intervene between each shovelful to allow the fresh coal to get to burning and to maintain the high temperature in the fire-box.
57. Q. When and why should you wet the coal on the tender?
A. Coal should be wet for the purpose of cleanliness to keep dust from flying and because moderately wet coal gives out more heat for the reason that there is not so much fine coal drawn through the tubes. It should be wet as often as necessary to accomplish these purposes.
58. Q. What are the advantages of a large grate surface?
A. Greater heating surface, lighter fire and more complete combustion are possible with the larger grate surface, because a larger amount is burning at one time at a slower rate of combustion.
59. Q. Why are grates made to shake, and how, when and where should they be shaken?
A. For the purpose of breaking any clinkers that might form and to shake out all refuse from the grates. The best time to shake grates is when throttle is closed, as there is no exhaust to carry the unconsumed gases and sulphur through the flues into the front end, which is liable to choke or clog up netting and cause a steam failure. Grates should not be shaken while passing over bridges, near lumber or hay yards or through prohibited territory.
60. Q. Do you understand that coal furnished represents money invested, and should be fired economically and not allowed to fall out of the gangway?
A. The fuel of locomotives is property and represents money invested the same as do buildings, rolling stock, etc.; careless or inefficient firemen who waste fuel destroy property as certainly as though cars or engines were smashed up. The coal should be carefully raked off the deck and in from the gangways; it should not be allowed to fall, as it is wasted and dangerous to people near the track. The deck should be kept clean for greater comfort and convenience.
61. Q. Is is objectionable to fill the tanks too full of coal or overflow tank at standpipes or water tanks?
A. It is. Tanks filled too full of coal are dangerous and a great waste of coal, as the jar when running will cause a part of it to fall off; water overflowing from tanks results in washing away the ballast and in cold weather freezes over the tracks.
62. Q. What are the duties of a fireman on arrival at the terminal?
A. Different roads have different assigned duties for the firemen to perform. They should leave the cab, boiler head, oil cans and deck in a clean condition, boiler full of water, enough fire and steam, so that the hostler will not be required to put in fuel while the engine is in his charge; should know that throttle valve is securely closed, reverse lever in center of quadrant, cylinder cocks open, and if equipped with independent brake, it to be applied; in fact, it is an excellent opportunity for a mechanical officer to judge the ability of the fireman and future engineer.